Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 171
Filtrar
1.
Vet Ophthalmol ; 26 Suppl 1: 59-71, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36057776

RESUMO

OBJECTIVE: To characterize the ocular surface parameters and determine the prevalence of ocular pathology in Shih Tzu dogs. ANIMAL STUDIED: Fifty Shih Tzu dogs (28 male, 22 female). PROCEDURES: Each dog underwent a complete ophthalmic examination (recording any pathology) and a series of diagnostics, allowing for a 10 min-interval between tests: intraocular pressure (IOP), blink rate, palpebral fissure length (PFL), corneal tactile sensation (CTS), Schirmer tear test and nasolacrimal reflex without (STT-1, NL-STT1) and with topical anesthesia (STT-2, NL-STT2), tear ferning, strip meniscometry test (SMT), tear film breakup time (TFBUT), and punctate fluorescein staining (PFS) of the cornea. RESULTS: Mean ± SD test values were as follows: IOP (17.9 ± 3.7 mmHg), blink rate (2.4 ± 1.4 blinks/min), PFL (23.8 ± 1.8 mm), CTS (1.8 ± 0.7 cm), STT-1 (22.0 ± 5.5 mm/min), NL-STT1 (24.2 ± 4.7 mm/min), STT-2 (16.9 ± 6.5 mm/min), NL-STT2 (18.5 ± 7.5 mm/min), SMT (7.5 ± 3.5 mm/5 s), TFBUT (5.3 ± 2.4 s), tear ferning (1.3 ± 0.7), and PFS (1.6 ± 0.6). PFL was significantly greater in male vs. female Shih Tzus (p< .001). Age was negatively correlated with TFBUT results (r = -0.31, p = .027). Lagophthalmos was observed in 82% eyes. Ocular surface pathology was common, including adnexal abnormalities (100% eyes with caruncular trichiasis and medial lower lid entropion) and corneal opacification (27% pigmentation, 20% fibrosis, 12% neovascularization). CONCLUSIONS: Qualitative tear film deficiency (low TFBUT), along with several anatomical abnormalities that promote ocular irritation and reduce globe protection, together help explain the concerningly high prevalence of ocular surface disease in the Shih Tzu breed. Prophylactic measures (e.g., medial canthoplasty, topical lubrication) could be considered to improve ocular health in Shih Tzus.


Assuntos
Oftalmopatias , Masculino , Cães , Feminino , Animais , Oftalmopatias/diagnóstico , Oftalmopatias/veterinária , Lágrimas , Técnicas de Diagnóstico Oftalmológico/veterinária , Córnea , Pálpebras , Fluoresceína
2.
J Equine Vet Sci ; 120: 104162, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36343832

RESUMO

This study sought to compare the Schirmer Tear Test (STT)-1 results at 30 (STT30) versus 60 (STT60) seconds in healthy horses. This study included a total of 56 healthy horses. STT-1 was performed in both eyes, right eye first, and the wetting lengths were measured in STT30 and STT60. To evaluate the reduction of the initial reflex phase, the wetting length velocity was measured during the first 30 seconds. The effects of eye, age, weight, sex, and ambient temperature and humidity on STT values were evaluated. Mean (standard deviation) STT30 and STT60 were 19.06 (3.88) and 24.26 (4.50) mm. There was a linear correlation between the STT 30 and STT60, expressed according to the following equation: STT60 = 2.20 + 1.18 × STT30 (P = .001). STT30 or STT60 values did not vary between the sexes or correlate with age, weight, ambient temperature, or humidity. In conclusion, STT30 allows for an accurate, reliable, and applicable diagnosis of tear production compared with the standard STT60 value. The proposed method is shorter and may be a suitable alternative to the 1-min test.


Assuntos
Técnicas de Diagnóstico Oftalmológico , Lágrimas , Animais , Cavalos , Técnicas de Diagnóstico Oftalmológico/veterinária , Valores de Referência
3.
Vet Ophthalmol ; 24(5): 533-542, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34554632

RESUMO

PURPOSE: To provide a descriptive investigation about relevant features of the crested caracara's eye (Caracara plancus) and bony orbit, as well as provide data for ophthalmic tests. METHODS: Morphological observations and the following diagnostic tests were performed: Schirmer tear test (STT), conjunctival flora evaluation, corneal touch threshold (CTT), intraocular pressure (IOP), central corneal thickness (CCT), B-mode ocular biometry, palpebral fissure length (PFL), and corneal diameter (CD) in 19 healthy birds, plus two macerated skulls. Not all birds were used for each test. RESULTS: STT: 7.84 ± 3.05 mm/min; CTT: 2.46 ± 1.10 cm; IOP: 19.18 ± 3.07 mmHg; CCT: 0.31 ± 0.02 mm; PFL: 13.32 ± 1.06 mm; CD: 10.26 ± 2.43 mm; Axial globe length: 1.89 ± 0.06 cm; Anterior chamber depth: 0.27 ± 0.06 cm; Lens axial length: 4.55 ± 0.06 cm; Vitreous chamber depth: 1.2 ± 0.07 cm. The most frequent conjunctival bacterial isolates were Corynebacterium sp. (10/23.8%), Staphylococcus sp. (9/21.42%), Streptococcus sp. (7/16.6%), and E. coli (7/16.66%). The large lateral part of the palatine bone likely plays a role in the ventral protection of the globe against the impact of prey. Observed results are generally reflective of increased body mass compared to other Falconiformes, with values approaching those of similar sized Accipitriformes. CONCLUSIONS: These data may help veterinarians recognize peculiar morphologic features and perform a more accurate diagnosis of eye diseases of this avian species.


Assuntos
Oftalmopatias/veterinária , Olho/anatomia & histologia , Falconiformes/anatomia & histologia , Animais , Córnea/fisiologia , Técnicas de Diagnóstico Oftalmológico/veterinária , Olho/microbiologia , Oftalmopatias/diagnóstico , Oftalmopatias/microbiologia , Feminino , Masculino , Fenômenos Fisiológicos Oculares , Órbita/anatomia & histologia , Lágrimas
4.
Vet Ophthalmol ; 24(3): 218-228, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33596337

RESUMO

PURPOSE: Review octopus ocular anatomy and describe the histopathologic findings in three octopuses diagnosed with phakitis and retinitis. ANIMALS: Two common octopuses (Octopus vulgaris) and one giant Pacific octopus (Enteroctopus dofleini) with a history of ophthalmic disease. METHODS: A literature search was performed for the ocular anatomy section. Both eyes from all three octopuses, and two control eyes, were submitted for histopathologic evaluation. Hematoxylin and eosin stain was used for standard histopathologic evaluation; GMS stain was used to screen for fungi, gram stain for bacteria; and Fite's acid fast stain for acid fast bacteria. RESULTS: Anatomically, the anterior chamber of the octopus has direct contact with ambient water due to an opening in the dorsal aspect of a pseudocornea. The octopus lens is divided into anterior and posterior segments. The anterior half is exposed to the environment through the opening into the anterior chamber. Neither part of the lens has a lens capsule. The retina is everted, unlike the inverted vertebrate retina, and consists of just two layers. Histopathology revealed inflammatory phakitis and retinitis of varying severity in all six eyes of the study animals. No intraocular infectious organisms were recognized but one common octopus eye had clusters of coccidian parasites, identified as Aggregata sp., in extraocular tissues and blood vessels. CONCLUSION: We describe inflammatory phakitis and retinitis in two species of octopuses. The underlying cause for the severe intraocular response may be direct intraocular infection, water quality, an ocular manifestation of a systemic disease, or natural senescence.


Assuntos
Octopodiformes/anatomia & histologia , Retinite/veterinária , Animais , Técnicas de Diagnóstico Oftalmológico/veterinária , Feminino , Masculino , Retinite/diagnóstico
5.
Open Vet J ; 11(4): 695-699, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-35070866

RESUMO

BACKGROUND: The surface of the eye is covered by the preocular tear film, which is critical for maintaining a normal, healthy, visual, and comfortable vision. The Schirmer tear test (STT) and, more recently, strip meniscometry (SM) are used to evaluate tear production. AIM: To establish the normal values for STT and SM in healthy cats and to discover the correlation between these tests. METHODS: A total of 25 mixed breed cats, aging from 8 months to 13 years of both genders (10 females and 15 males) were included in the study. All the cats were assigned to the study as being both clinically and ophthalmologically healthy. For the SM test, the tip of the strip was used to evaluate the meniscus without touching the eyelid or the cornea for 5 seconds. After a full tear washout period of 10 minutes, the STT was performed using a standard STT strip. RESULTS: In the right eyes, the mean ± standard deviation (SD) of SM was 4.32 ± 2.27 mm/5 seconds, and in the left eyes it was 5.04 ± 2.24 mm/5 seconds (for both eyes combined: 4.68 ± 2.26 mm/5 seconds), with a median of 4 in both eyes; the reference values ranged from 4.04 to 5.32 mm/5 seconds. No significant differences were recorded in the SM between the right and left eyes of the cats when using the SM (p > 0.05). When the STT was used, the mean ± SD for the cats' right eyes was 12.16 ± 4.04 mm/minute, and for the left eyes, it was 12.76 ± 4.1 mm/minute (for both eyes combined: 12.46 ± 4.20 mm/minute), with a median of 13.50 for both eyes. Reference values were calculated and ranged from 11.27 to 13.65 mm/minute. No significant differences were recorded between the STT for the right and left eyes (p > 0.05). CONCLUSION: Both tests can, therefore, be used to assess tear production in cats. For more precise results, SM should be evaluated according to the cat's eye position-whether it is a brachiocephalic cat or a normaloid cat-and according to the age. In all cases, STT and SM should be evaluated according to the animal's clinical status and the results of other diagnostic tools.


Assuntos
Doenças do Gato , Doenças do Aparelho Lacrimal , Animais , Gatos , Técnicas de Diagnóstico Oftalmológico/veterinária , Feminino , Doenças do Aparelho Lacrimal/veterinária , Masculino , Valores de Referência , Lágrimas
6.
Cornea ; 40(5): 578-583, 2021 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-32947393

RESUMO

PURPOSE: To retrospectively evaluate the clinical data, diagnostic tests, treatments, and outcomes for dogs with corneal endothelial dystrophy (CED) and determine risk factors for CED when compared with a canine reference population. METHODS: Medical records of 99 dogs (1991-2014) diagnosed with CED at the University of California Davis Veterinary Medical Teaching Hospital were reviewed and compared with 458,680 dogs comprising the general hospital population during the study period. Retrieved data included signalment, examination findings, diagnoses, treatments, and outcomes associated with CED. The exact Pearson χ2 test or exact Kruskal-Wallis test was used to compare parameters between the groups. Progression of corneal edema was assessed using 3 independent Kaplan-Meier curves, identifying clinically significant changes in corneal opacity. RESULTS: Boston terriers, German wirehaired pointers, and Dachshunds were overrepresented in the CED-affected group, whereas Labradors were underrepresented. Dogs older than 11 years were overrepresented in the CED-affected group, whereas intact dogs were underrepresented. Surgical intervention was performed (n = 11) based on the severity of disease and secondary complications from CED. Median time to progression of corneal edema was 1) 368 days when an at-risk eye initially without edema developed edema at a subsequent visit, 2) 701 days when there was progression from mild to marked corneal edema, and 3) 340 days when there was progression from focal to diffuse corneal edema. CONCLUSIONS: Many CED-affected dogs progress over months to years without surgical intervention, making dogs with CED a useful model for studying genetic predispositions and development of novel therapeutics for Fuchs endothelial corneal dystrophy.


Assuntos
Distrofias Hereditárias da Córnea/veterinária , Edema da Córnea/veterinária , Doenças do Cão/diagnóstico , Animais , Antibacterianos/uso terapêutico , Anti-Inflamatórios/uso terapêutico , Distrofias Hereditárias da Córnea/diagnóstico , Distrofias Hereditárias da Córnea/tratamento farmacológico , Edema da Córnea/diagnóstico , Edema da Córnea/tratamento farmacológico , Paquimetria Corneana/veterinária , Técnicas de Diagnóstico Oftalmológico/veterinária , Doenças do Cão/tratamento farmacológico , Cães , Feminino , Masculino , Microscopia Confocal/veterinária , Midriáticos/uso terapêutico , Pomadas/administração & dosagem , Estudos Retrospectivos
7.
Comput Math Methods Med ; 2020: 6689023, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33381221

RESUMO

AIM: To identify the guinea pig eyeball with edge detection and curve fitting and devise a noncontact technology of measuring ocular morphological parameters of small experimental animal. METHODS: Thirty-nine eyeballs of guinea pig eyeballs were photographed to obtain the anterior and posterior surface; transverse and sagittal planes after the eyeballs were eviscerated. Next, the eyeball photos were input into digital image analysis software; the corresponding photo pixels-actual length ratio was acquired by a proportional scale. The contour lines of the eyeballs were identified by edge detection technology; conic curve fitting was applied to fit the contour line of the eyeball. The maximum and minimum diameters, the horizontal and vertical diameters, eccentricity, tilt angle, cross-sectional area, equatorial circumference, retrobulbar equatorial maximum length, corneal radius of curvature (CRC) in central region, and the whole cornea were calculated according to the geometric principles. The corneal data of in vitro study were compared with the in vivo results. RESULTS: The contour line of the selected guinea pig eye was identified correctly by edge detection. There were no significant differences between anterior and posterior surfaces of one eyeball in the maximum diameters, eccentricity, cross-sectional area, equatorial circumference, and tilt angle (P > 0.01). There were significant differences of eccentricity and CRC between central region and the whole cornea (P < 0.01). There were no significant differences between keratometer in vivo and cornea in vitro. CONCLUSION: It was feasible to measure an experimental animal eye in a noncontact way. Edge detection and curve fitting technology could accurately evaluate the ocular morphological parameters.


Assuntos
Olho/anatomia & histologia , Cobaias/anatomia & histologia , Animais , Biologia Computacional , Simulação por Computador , Córnea/anatomia & histologia , Técnicas de Diagnóstico Oftalmológico/veterinária , Humanos , Processamento de Imagem Assistida por Computador/estatística & dados numéricos , Conceitos Matemáticos , Modelos Anatômicos , Modelos Animais , Fotografação
8.
Vet Ophthalmol ; 23(6): 1031-1035, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33058382

RESUMO

OBJECTIVE: To determine whether wetting length of Schirmer tear test (STT) strips varies by commercial manufacturer of test. ANIMALS STUDIED: Ten normal female beagle cross-breed dogs. PROCEDURES: Schirmer tear test strips from four commercial manufacturers were used to assess wetting lengths in-vitro when exposed to a set volume of water over 1 minute. Digital photography was used to assess the total surface area of Schirmer strips from each manufacturer. Schirmer tear test type 1 was performed on normal dogs over 1 minute with STT strips from the same four commercial manufacturers in a randomized crossover design. ANOVA was used to detect differences between strips from different manufacturers. RESULTS: Significant differences in wetting length were found between STT strips from different manufacturers in-vitro (P < .0001) and in-vivo (P < .0001). STT wetting lengths for the in-vitro experiments (mean ± SD) were 21.2 ± 0.8 mm (Amcon Laboratories), 27.8 ± 2.7 mm (Merck Animal Health), 30.0 ± 1.7 mm (HUB pharmaceuticals), and 31.5 ± 2.3 mm (Gulden Ophthalmics). STT wetting lengths for the experiments in live dogs (mean ± SD) were 17.5 ± 3.4 mm (Amcon Laboratories), 24.8 ± 3.9 mm (Merck Animal Health), 26.5 ± 3.7 mm (HUB pharmaceuticals), and 24.0 ± 3.9 mm (Gulden Ophthalmics). The surface area of STT strips were found to vary between different manufacturers. CONCLUSIONS: Schirmer tear test type 1 results in dogs are affected by choice of STT strip commercial manufacturer. It is proposed that guidelines are created for the standardization of future STT strip production.


Assuntos
Técnicas de Diagnóstico Oftalmológico/veterinária , Cães/fisiologia , Fitas Reagentes , Lágrimas , Animais , Feminino
9.
Vet Clin North Am Small Anim Pract ; 50(6): 1261-1276, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32854977

RESUMO

Small animal ocular emergencies vary from relatively benign to potentially vision or life threatening, with significant overlap in clinical signs. Careful ophthalmic examination in dim light conditions with a bright light source and competent patient head restraint are crucial to properly diagnosing ocular disease. Adjunctive ophthalmic diagnostic testing should be performed to rule out corneal ulceration, glaucoma, and dry eye before empiric topical antibiotic or steroid medications are prescribed. Most emergency cases present because of ocular redness, cloudiness, discomfort, apparent bulging, or vision loss; categorizing differential diagnoses on this basis can be helpful to the emergency clinician.


Assuntos
Doenças do Gato/terapia , Técnicas de Diagnóstico Oftalmológico/veterinária , Doenças do Cão/terapia , Oftalmopatias/veterinária , Traumatismos Oculares/veterinária , Animais , Gatos , Cães , Emergências/veterinária , Oftalmopatias/terapia , Traumatismos Oculares/terapia
10.
Vet Ophthalmol ; 23(5): 923-926, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32573896

RESUMO

OBJECTIVE: To investigate the effects of environmental temperature and relative humidity on tear test results in dogs. ANIMALS STUDIED: 22 normal dogs. PROCEDURES: Routine Schirmer tear tests (STT1) and phenol red thread tests (PRTT) were administered to normal dogs in four environmental conditions with different relative humidity (RH) and temperature (T). Environmental conditions (mean ± SD) included the following: normal indoor (RH = 49 ± 4%, T = 72 ± 2°F), outdoor (RH = 62 ± 11%, T = 85 ± 6°F), indoor high humidity (RH = 85 ± 6%, T = 71 ± 1°F), and indoor low humidity (RH = 39 ± 2%, T = 76 ± 1°F). ANCOVA models were used to assess for significant associations between tear test readings and RH/T (P < .05). RESULTS: A significant, direct positive relationship between RH and STT1 results was detected (y = 0.04909*X + 19.11, P = .006) but not between T and STT1. There was no significant relationship between PRTT and RH or T. CONCLUSIONS: These results suggest that STT1 but not PRTT is affected by RH and that T does not influence STT1 or PRTT results in normal dogs. RH is unlikely, however, to cause clinically significant effects on STT1 readings in normal dogs when performed in average indoor conditions. Future studies should investigate the influence of RH on STT1 readings obtained in dogs with keratoconjunctivitis sicca.


Assuntos
Lágrimas , Animais , Técnicas de Diagnóstico Oftalmológico/veterinária , Doenças do Cão/fisiopatologia , Cães , Síndromes do Olho Seco/fisiopatologia , Síndromes do Olho Seco/veterinária , Feminino , Umidade , Masculino , Valores de Referência
11.
Vet Ophthalmol ; 23(4): 624-631, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32386097

RESUMO

OBJECTIVE: To evaluate a grading scheme for conjunctival staining patterns with lissamine green ocular dye in the diagnosis of tear film deficiencies in dogs. PROCEDURES: Client-owned and research colony dogs were enrolled in a prospective study between February and October 2018 in which slit-lamp biomicroscopy, Schirmer tear test (STT), tear film breakup time (TFBUT), conjunctival lissamine green staining (LGS), and intraocular pressure (IOP) measurement were performed in both eyes of all dogs. Lissamine green staining of the temporal bulbar conjunctiva was graded from 0-3, with a higher grade corresponding to an increased stain intensity. RESULTS: Fifty-four dogs (107 eyes), comprising 31 males and 23 females with a mean age of 5.0 ± 3.9 years (range 0.5-14.3), were enrolled in the study. STT was <15 mm/min in 21 eyes and ≥15 mm/min in 86 eyes. Lissamine green staining grade for eyes with a STT of <15 mm/min (2.0 ± 0.9) was significantly higher than for eyes with a STT ≥15 mm/min (0.2 ± 0.7) (P < .001). TFBUT for eyes with a STT <15 mm/min (6.5 ± 4.4 seconds) was significantly shorter than for eyes with a STT ≥ 15 mm/min (16.1 ± 3.6 seconds) (P < .001). As LGS grade increased, both STT (P < .001) and TFBUT (P < .001) significantly decreased. CONCLUSIONS: A higher LGS grade was significantly associated with a lower STT and more rapid TFBUT in dogs. Lissamine green ocular dye can be considered as an adjunctive diagnostic test when evaluating tear film deficiency in dogs.


Assuntos
Túnica Conjuntiva/patologia , Doenças do Cão/diagnóstico , Síndromes do Olho Seco/veterinária , Animais , Técnicas de Diagnóstico Oftalmológico/veterinária , Cães , Síndromes do Olho Seco/diagnóstico , Feminino , Corantes Verde de Lissamina , Masculino , Soluções Oftálmicas , Valor Preditivo dos Testes , Estudos Prospectivos
12.
Vet Ophthalmol ; 23(3): 534-543, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32162773

RESUMO

OBJECTIVE: To characterize diagnostic findings, test-retest repeatability, and correlations among lacrimal tests in dogs of diverse cephalic conformations. ANIMAL STUDIED: Fifty healthy dogs (25 brachycephalic, 25 nonbrachycephalic). PROCEDURES: A series of diagnostics were performed in each dog, allowing for a 10-minute interval between tests and repeating each test 24 hours later under similar conditions: corneal tactile sensation (CTS), strip meniscometry test (SMT), phenol red thread test (PRTT), endodontic absorbent paper point tear test (EAPPTT), Schirmer tear test-1 without (STT-1) or with nasolacrimal stimulation (NL-STT1), and Schirmer tear test-2 (STT-2). RESULTS: Mean ± SD test values were lower in brachycephalic vs. nonbrachycephalic dogs (except for SMT; 7.4 ± 2.0 mm/5 seconds vs 7.3 ± 2.4 mm/5 seconds), with statistically significant differences noted for CTS (1.8 ± 0.5 cm vs 3.4 ± 0.8 cm), PRTT (37.2 ± 4.0 mm/15 seconds vs 41.1 ± 5.5 mm/15 seconds), STT-1 (20.1 ± 3.4 mm/min vs 23.3 ± 5.7 mm/min), STT-2 (13.0 ± 3.4 mm/min vs 16.9 ± 3.9 mm/min), and NL-STT1 (23.2 ± 3.6 mm/min vs 27.1 ± 5.4 mm/min), and nonsignificant differences for EAPPTT (16.6 ± 2.7 mm/15 seconds vs 17.5 ± 2.9 mm/15 seconds). Nasolacrimal stimulation increased STT-1 values by 18% on average. Correlations among tests were generally weak to moderate (r < .70) except for a strong correlation between STT-1 and NL-STT1 (r = .83, P < .001). Test reliability was good although test-retest repeatability was generally poor to moderate, as depicted by low intraclass correlation coefficients (ICC ≤ 0.75) and wide 95% limits of agreement, except for CTS (ICC = 0.91). CONCLUSIONS: Corneal sensitivity and aqueous tear secretion are lower in brachycephalic dogs. A comprehensive assessment of the ocular surface requires the combination of several diagnostic tests. The nasolacrimal reflex may provide a useful diagnostic and therapeutic tool in dogs.


Assuntos
Ducto Nasolacrimal/fisiologia , Lágrimas/fisiologia , Animais , Técnicas de Diagnóstico Oftalmológico/veterinária , Cães , Feminino , Masculino , Linhagem , Fitas Reagentes , Reprodutibilidade dos Testes
13.
Vet Ophthalmol ; 23(2): 234-244, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31562703

RESUMO

OBJECTIVE: The purpose of this study is to evaluate a group of young commercially available Skinny pigs, to gain information regarding ocular findings in this breed of guinea pig. Comparisons of ocular findings are to be made between Skinny pigs and haired guinea pigs. ANIMAL STUDIED: Ten haired guinea pigs and ten Skinny pigs were examined. PROCEDURE: A complete ophthalmic examination including Schirmer tear test-II (STT-II), phenol red thread test (PRTT), rebound tonometry with TonoVet PLUS, Fluorescein and Rose Bengal stain was performed. Microbiology swabs for aerobic bacterial growth were collected from conjunctiva of both eyes prior to the ophthalmic examination. RESULTS: The ophthalmic examination revealed seven abnormal ocular findings: trichiasis, mucopurulent discharge, hyperemia/chemosis of the conjunctiva, corneal fibrosis, corneal vascularization, and foreign body on the cornea or conjunctiva. Skinny pigs had a significantly higher amount of mucopurulent discharge (P = .0133) and a significantly higher STT-II (P < .001) than haired guinea pigs. Although not significant, trichiasis, keratitis with corneal vascularization, and foreign body presence were more common in Skinny pigs. Significantly more Skinny pigs had Pasteurellaceae isolated from their conjunctiva than haired guinea pigs (P = .0112). Antimicrobial susceptibility for the five Pasteurellaceae organisms isolated revealed susceptibility toward oxytetracycline, tobramycin, ciprofloxacin, and ofloxacin, whereas resistance was found toward erythromycin, trimethoprim-sulfamethoxazole, and moxifloxacin. CONCLUSION: Young Skinny pigs have a higher risk of Pasteurellaceae-associated conjunctivitis. Oxytetracycline, tobramycin, ciprofloxacin, and ofloxacin were identified as topical antibiotics that may be useful for Pasteurellaceae-associated conjunctivitis in Skinny pigs.


Assuntos
Testes Diagnósticos de Rotina/veterinária , Cobaias , Tonometria Ocular/veterinária , Animais , Infecções Bacterianas/microbiologia , Infecções Bacterianas/veterinária , Conjuntivite/microbiologia , Conjuntivite/veterinária , Técnicas de Diagnóstico Oftalmológico/veterinária , Displasia Ectodérmica/diagnóstico , Displasia Ectodérmica/veterinária , Oftalmopatias/diagnóstico , Oftalmopatias/veterinária , Feminino , Cabelo , Pressão Intraocular , Masculino , Fenolsulfonaftaleína , Lágrimas
14.
Vet Rec ; 186(10): 321, 2020 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-31619512

RESUMO

BACKGROUND: Past studies have shown that 5-mm Schirmer tear tests (STTs) are difficult to interpret in guinea pigs. Modified 2.5-mm STT strips are more adequate for measuring the small volume of tear production in these animals. The aim of this study was to establish reference values for the modified 2.5-mm STT strips. METHODS: Modified STT measurements were performed in random order in both eyes of 50 guinea pig patients. The wetting of the strip was noted at 30 seconds and at 1 minute. RESULTS: The mean±sd STT values for both eyes were 7.58±3.19 mm at 30 seconds and 10.42±3.92 mm at 60 seconds. The median was 8 mm at 30 seconds and 10 mm at 60 seconds for both eyes. Animals under one year of age had lower STT values. STT values at 30 and 60 seconds can both be used. Both eyes should be measured when possible. CONCLUSION: The authors recommend values above 8 mm at 30 seconds and 10 mm at 60 seconds to be considered normal when using a 2.5-mm STT strip. There are ambiguous areas at 5-8 mm and 6-10 mm. If in these ranges the results should be combined with clinical signs and judgement.


Assuntos
Técnicas de Diagnóstico Oftalmológico/veterinária , Cobaias/fisiologia , Lágrimas/metabolismo , Animais , Feminino , Masculino , Valores de Referência
15.
Parasit Vectors ; 12(1): 505, 2019 Oct 30.
Artigo em Inglês | MEDLINE | ID: mdl-31666101

RESUMO

BACKGROUND: Countries of eastern Europe are considered, due to several risk factors, more vulnerable to infections with newly (re)emerging pathogens. During the last decade, in several European countries, reports of autochthonous cases of ocular thelaziosis due to Thelazia callipaeda have been published, posing a great concern from both veterinary and public health perspective. However, in the Republic of Moldova only limited epidemiological data are available regarding zoonotic vector-borne pathogens and, until now, no data exist on the zoonotic nematode T. callipaeda. METHODS: In September 2018, an 11-year-old dog, mixed-breed, intact male was referred to a private veterinary clinic from Chișinau, Republic of Moldova, with a history of 2 weeks of an ocular condition affecting the right eye. The ophthalmological exam revealed the presence of nematode parasites in the conjunctival sac and under the third eyelid. The collected parasites were identified by morphological techniques and molecular analysis. RESULTS: A total of 7 nematodes were collected, and 5 females and 2 males of T. callipaeda were identified morphologically. The BLAST analysis confirmed the low genetic variability of this parasite in Europe. The travel history of the patient allowed us to confirm the autochthonous character of the case. CONCLUSIONS: To the best of our knowledge, this is the first report of thelaziosis in dogs from the Republic of Moldova, which confirms the spreading trend of T. callipaeda and the existence of an autochthonous transmission cycle of this zoonotic parasite in the country.


Assuntos
Doenças do Cão/parasitologia , Infecções Oculares Parasitárias/veterinária , Infecções por Spirurida/veterinária , Thelazioidea/isolamento & purificação , Animais , Diagnóstico Diferencial , Técnicas de Diagnóstico Oftalmológico/veterinária , Cães , Infecções Oculares Parasitárias/parasitologia , Feminino , Aparelho Lacrimal/parasitologia , Masculino , Moldávia , Membrana Nictitante/parasitologia , Exame Físico/veterinária , Infecções por Spirurida/parasitologia , Thelazioidea/classificação , Thelazioidea/genética
16.
Vet Rec ; 184(26): 799, 2019 06 29.
Artigo em Inglês | MEDLINE | ID: mdl-31055379

RESUMO

BACKGROUND: The purpose of this study was to evaluate the values of Schirmer tear test (STT) and determine effects of age, life stage, sex, breed and neuter status on tear production in healthy cats. METHODS: Three hundred and forty-three domestic shorthair (DSH) and Persian cats, 50 days through 18 years old, were examined in this study. STT I was used to measure tear production in both eyes of each cat. RESULTS: A mean STT 14.9±4.8 mm/min was calculated for the eyes of all cats. There was a significant difference between STT values in kittens (≤6 months old) and cats of other age groups (P<0.001). A substantial number of cats with clinically normal eyes had STT values less than 10 mm/min. No significant difference was found between males (14.7±5.0 mm/min) and females (15.1±4.5 mm/min) in STT values (P=0.46). Significant differences were found between entire (14.4±4.2 mm/min) and neutered (16.2±4.1 mm/min) cats (P=0.001), and between STT values of DSH (14.6±5.0 mm/min) and Persian (16.5±3.1 mm/min) cats in the study population (P=0.001). CONCLUSIONS: This study documents the average STT values for a sizeable feline population demonstrating that, in contradistinction to the situation in dogs, a number of cats with clinically normal eyes have STT values below 10 mm/min.


Assuntos
Gatos/fisiologia , Técnicas de Diagnóstico Oftalmológico/veterinária , Lágrimas/fisiologia , Fatores Etários , Animais , Cruzamento , Castração/estatística & dados numéricos , Castração/veterinária , Feminino , Masculino , Fatores Sexuais
17.
Vet Ophthalmol ; 22(6): 864-871, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30900351

RESUMO

OBJECTIVES: The strip meniscometry test (SMT) is a novel method for quantitative measurement of tear volume with only five seconds. We aimed to evaluate clinical correlations of SMT with the gold standard Schirmer tear test (STT) and phenol red thread test (PRT) in dogs, including normal and tear-deficient eyes. ANIMALS STUDIED: Left eyes from 621 outpatient dogs with and without ocular disorders were evaluated. PROCEDURES: Each subject underwent SMT, PRT, and STT without topical anesthesia in the described order with five-minute intervals. The total population was divided into four groups by classifying tear deficiency severity based on STT results: "severe" (0-5 mm/min), "moderate" (6-10 mm/min), "subclinical" (11-14 mm/min), and "normal" (15 or more mm/min). RESULTS: The strongest correlation coefficient was found between SMT-STT (0.676), followed by PRT-STT (0.637) and SMT-PRT (0.600) pairs. Mean(SD) scores of SMT, PRT, and STT in total population were 9.47 (4.08) mm/5 s, 33.30 (8.52) mm/15 s, and 16.47 (7.01) mm/min. Significant differences were found among STT-classified groups, both using SMT and PRT results. Receiver operating characteristic (ROC) curves revealed that SMT better agreed with STT than PRT; agreement increased with increasing STT severity. A cutoff for SMT was identified at 10 mm/5 s to discriminate normal eyes from tear-deficient eyes, yielding high sensitivities and acceptable specificities. CONCLUSIONS: SMT could be superior to PRT for discriminating tear-deficient eyes. The high sensitivity of SMT could be useful as an initial diagnostic tool to rule out normal eyes with the short testing time.


Assuntos
Técnicas de Diagnóstico Oftalmológico/veterinária , Doenças do Cão/diagnóstico , Oftalmopatias/veterinária , Fenolsulfonaftaleína , Fitas Reagentes , Lágrimas/fisiologia , Animais , Corantes , Cães , Oftalmopatias/diagnóstico , Feminino , Masculino
18.
J Vet Med Sci ; 81(4): 538-540, 2019 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-30745521

RESUMO

Medetomidine, an α2-adrenoceptor agonist, was reported to decrease tear flow in some species. However, there are no reports about the effect of medetomidine on tear flow in pigs. The purpose of this study was to elucidate it. The study was performed in 10 clinically normal female Landrace pigs aged 3 months. Tear flow was measured by the Schirmer tear test (STT) I before (baseline) and 15 and 30 min after intramuscular administration of 80 µg/kg medetomidine. Compared to the STT I value at baseline, the value decreased significantly at 30 min after administration in both the left and right eyes. In pigs treated with medetomidine, an artificial tear solution or ophthalmic gel should be applied to protect the ocular surface.


Assuntos
Agonistas de Receptores Adrenérgicos alfa 2/administração & dosagem , Medetomidina/administração & dosagem , Sus scrofa/fisiologia , Lágrimas/efeitos dos fármacos , Animais , Técnicas de Diagnóstico Oftalmológico/veterinária , Feminino
20.
Pesqui. vet. bras ; 39(1): 61-65, Jan. 2019. tab, ilus
Artigo em Inglês | LILACS, VETINDEX | ID: biblio-990233

RESUMO

The establishment of parameters for tear production in different species is important for better understanding eye´s health and is one of the components of the ophthalmic semiological technique. Particularities derived from the anatomophysiology of non-domestic species induce the search for more reliable methodologies. The aim was to evaluate and compare tear production of white-eared opossum (Didelphis albiventris) and Brazilian common opossum (Didelphis aurita) by three different methods. Fifteen individuals of each species, juveniles, healthy, of both sexes, with 60 to 90 days of life, were physically restrained. Phenol red thread test (PRTT), endodontic absorbent paper point tear test (EAPPTT) and modified -Schirmer tear test (mSTT) were performed. PRTT was the most difficult to perform because of the wire malleability, while EAPPTT was more feasible for both species. The median ± semi-quartile range for PRTT were 19.79±2.61mm/15 "and 5.22±2.92mm/15", for EAPPTT were 16.25±1.82mm/min and 10.9±3.04mm/min, and for STTm were 0±1.63mm/min and 0±1.63mm/min for white-eared opossum and Brazilian common opossum respectively. There was no difference between the right and left eye neither sex. A significant difference was obtained for the same test to different species. No significant correlation was found between the tests for both species. The description of tear production parameters for juvenile white-eared opossum and Brazilian common opossum may be used as a tool, which will allow the early diagnosis of ocular diseases.(AU)


O estabelecimento do parâmetro de produção lacrimal nas diferentes espécies é importante para o entendimento da saúde do olho e é um dos componentes da semiotécnica oftálmica. Particularidades derivadas da anatomofisiologia das espécies não domésticas induzem a busca de metodologias que sejam mais fidedignas aos parâmetros. Objetivou-se com este estudo avaliar e comparar a produção lacrimal de gambás-de-orelha-branca (Didelphis albiventris) e gambás-de-orelha-preta (Didelphis aurita) por três diferentes métodos. Quinze indivíduos de cada espécie, juvenis, hígidos, de ambos os sexos, com 60 a 90 dias de vida, foram contidos fisicamente para realização do teste lacrimal do vermelho de fenol (TLVF), da ponta de papel absorvente estéril e do teste lacrimal de Schirmer modificado (TLSm). O TLVF foi o mais difícil de ser executado devido à maleabilidade do fio, enquanto a TEPA se mostrou mais exequível para ambas as espécies. A mediana ± intervalo semi-interquartil para o TLVF foi de 19,79±2,61mm/15" e 5,22±2,92mm/15", para a TEPA foram de 16,25±1,82mm/min e 10,93±3,04mm/min, e para o TLSm foram de 0±1,63mm/min e 0±1,63mm/min, para gambás-de-orelha-branca e gambás-de-orelha-preta, respectivamente. Não houve diferença entre o olho direito e esquerdo e nem quanto ao sexo. Obteve-se diferença significativa para um mesmo teste entre as espécies. Não foi encontrada correlação significativa entre os testes para ambas as espécies. A quantificação da porção aquosa da lágrima poderá auxiliar no diagnóstico precoce de doenças oculares nas espécies estudadas.(AU)


Assuntos
Animais , Gambás/fisiologia , Lágrimas/metabolismo , Técnicas de Diagnóstico Oftalmológico/veterinária , Fenolsulfonaftaleína
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...